光纖配線架(ODF)用于光纖通信系統(tǒng)中局端主干光纜的成端和分配,可方便地實現光纖線路的連接、分配和調度。隨著網絡集成程度越來越高,出現了集ODF、DDF、電源分配單元于一體的光數混合配線架,適用于光纖到小區(qū)、光纖到大樓、遠端模塊局及無線基站的中小型配線系統(tǒng)。
外觀結構
1、機架結構形式
1)機架結構有封閉式、半封閉式和敞開式。
2)機架高度分為2600mm、2200mm和2000mm三類。其寬度*選用120mm的整數倍,深度*選用300mm、450mm及600mm。
3)機架外形尺寸的偏差不超過±2mm;外表面對底部基準面的垂直度公差不大于3mm。
2、機械活動部分
機械活動部分應轉動靈活、插拔適度、鎖定可靠、施工安裝和維護方便。門的開啟角應不小于110°,間隙不大于3mm。
3、引入光纜彎曲半徑
引入光纜進入機架時,其彎曲半徑應不小于光纜直徑的15倍。
4、機架結構
結構應牢固,裝配應具有一致性和互換性,緊固件無松動。外露和操作部位的銳邊應倒圓角。
5、保護套、襯墊及纖芯和尾纖彎曲半徑
光纜光纖穿過金屬板孔及沿結構件銳邊轉彎時,應裝保護套及襯墊。纖芯、尾纖無論處于何處彎曲時,其曲率半徑應不小于30mm。
6、機架的表面
涂覆層應表面光潔,色澤均勻、無流掛、無露底;金屬件無毛刺銹蝕。